  • Procedure

PROGRAMMING PROCEDURE

 

To RPO 09008, without deadlocking.

 

1.    ENSURE all doors are closed but UNLOCKED .

 

2.    PRESS and HOLD remote button until LED stops flashing.

 

3.    RELEASE button, LED should light constantly .

 

4.    PRESS the remote button ONCE, LED should no longer be ON.

 

5.    TEST remote.

 

To RPO 09008 with deadlocking.

 

1.    ENSURE all door are CLOSED but UNLOCKED .

 

2.    PRESS and HOLD the LARGE remote button for 20 seconds.

 

3.    After 20 seconds, whilst keeping the LARGE button depressed, PRESS the SMALL button ONCE.

 

4.    RELEASE the LARGE button and LED will light constantly.

 

6.    PRESS the LARGE button once more.

 

7.    TEST remote.

 

For RPO 09009 onwards, remote is diagnostically programmed.

 

Resync procedure.

 

1.    PRESS and HOLD LOCK button on the remote.

 

2.    SWITCH ignition ON for 10 seconds.

 

3.    SWITCH ignition OFF, RELEASE LOCK button.

 

4.    TEST remote.